Materials and components
Loading components at the infeed
Operators load containers and closures at the infeed, right next to sterile product. A camera can check how each one is loaded against your line setup procedure, and a reviewer decides every case it opens.
The practice
In plain words
At the infeed, operators load containers and closures onto the filling line. They set each one where the line setup procedure shows and keep their gloves and gown off any surface that meets the product. Loading happens right beside sterile product, so a misplaced or touched component is a way for contamination to reach it.
Running in the demoPart of Materials and components
Why it matters
In the regulators' words
“Components and drug product containers and closures shall at all times be handled and stored in a manner to prevent contamination.”
“Personnel should not directly contact sterile products, containers, closures, or critical surfaces with any part of their gown or gloves.”
“Aseptic technique should be observed at all times, including the appropriate use of sterile tools for manipulations.”
“An intervention that is an integral part of the aseptic process and is required for either set-up, routine operation and/or monitoring (e.g. aseptic assembly, container replenishment, environmental sampling).”
The rule
The example rule from the demo
Rule R-02, version 1.0Example
Containers and closures are loaded as the line setup procedure shows: each component seated in its nest, trays level, and no touch on product-contact surfaces.
- How it is detected
- Trained detector. Checks how each component is placed and handled at the infeed.
- Detector
- loading 0.2.0Sample data
- Cameras
- CAM-02 RABS front, CAM-03 Component hopperExample
- Site procedure
- Filling line setup procedure, component loadingExample
The rule, cameras, procedure and detector are examples from the demo, shown as sample data. Your procedures set the real rule at setup, and your quality unit approves it.
How the camera sees it
What the camera has to see
A trained detector watches the infeed and checks how each component is placed and handled against the rule. When loading doesn't match it, the detector opens a case with the clip, and a reviewer decides what it means.
- Detection method: How the camera detects hand and object contact(opens conductscience.com)
What happens to a detection
From a detection to a signed record
A case opens
The detector opens a case with its own ID, the detection time from the site clock, the camera, area and shift, the rule and its version, and the detector version.
A reviewer decides
A trained reviewer watches the clip and confirms, dismisses or escalates the case with a reason from a fixed list. Only a quality lead closes an escalation.
Read more about a reviewer decidesThe event record
Each case prints as an event record: what the camera saw, the rule and its sources, and every decision, ready to attach to an investigation in your own system.
The report
The Aseptic Behavior Monitoring Report counts every case in the period, with trends and the audit trail, and your quality unit signs it.
EV-20260925-00625 Sep 2026 15:53:09 ET
Bottle tray loaded tilted against the guide rail.
A sample case from the demo. Sample data.
Status
Where it stands in the product
- Running in the demoComponents loaded incorrectly at the infeed. Running in the demo as condition C2, with example rule R-02 version 1.0 and detector loading 0.2.0. Sample data.
Sources
Every passage behind this practice
- 21 CFR 211.80(b)(opens the official source)Broader requirement this falls under. Checked 24 Sep 2026
- FDA aseptic guidance, page 17(opens the official source)Broader requirement this falls under. Checked 24 Sep 2026
- Annex 1, clause 8.16(opens the official source)Broader requirement this falls under. Checked 24 Sep 2026
- Annex 1, glossary: inherent interventions(opens the official source)Broader requirement this falls under. Checked 24 Sep 2026
Questions
Common questions
- Is loading components an intervention?
- Annex 1 lists container replenishment among its examples of inherent interventions, the ones that are part of the routine aseptic process. Your procedure decides which loading steps it treats that way.
- What does a loading case show the reviewer?
- The clip and frames, the camera, the time from the site clock, the rule and its version, and the detector and its version. The reviewer confirms, dismisses or escalates the case with a reason from a fixed list.
- Can we use our own loading procedure?
- Yes. The rule on this page is the demo example. At setup your team writes the rule from your line setup procedure, and your quality unit approves it.
See it with sample data
We show the review queue, a signed monitoring report, the audit trail review and the validation package, then answer your team's questions.