Materials and components

Loading components at the infeed

Operators load containers and closures at the infeed, right next to sterile product. A camera can check how each one is loaded against your line setup procedure, and a reviewer decides every case it opens.

Illustration, not camera footage. CAM-02 RABS front, 25 Sep 2026 15:53:09 ET. Front view through the RABS window at the line infeed: an operator places caps into the nests of the cap tray through a glove port, beside a conveyor of open, empty bottles. Subject 4 is tagged. Detection moment. Flagged: a cap placed in the cap tray sits tilted and out of its nest.OPEN BOTTLESCAP TRAYINFEEDHEPASubject 4Tray loaded tiltedCAM-02 RABS front25 Sep 2026 15:53:09 ETILLUSTRATIONT 0 s
A drawn illustration of a detection from the demo, not footage. In your system this is the recorded clip, kept on your site network. Sample data.

The practice

In plain words

At the infeed, operators load containers and closures onto the filling line. They set each one where the line setup procedure shows and keep their gloves and gown off any surface that meets the product. Loading happens right beside sterile product, so a misplaced or touched component is a way for contamination to reach it.

Running in the demoPart of Materials and components

Why it matters

In the regulators' words

21 CFR 211.80(b) asks for containers and closures to be handled at all times in a way that prevents contamination, and FDA's guidance asks operators never to touch them or other critical surfaces with their gown or gloves. Annex 1 counts container replenishment as an inherent intervention, done with aseptic technique.
“Components and drug product containers and closures shall at all times be handled and stored in a manner to prevent contamination.”
21 CFR 211.80(b)(opens the official source)Binding US regulationChecked 24 Sep 2026
“Personnel should not directly contact sterile products, containers, closures, or critical surfaces with any part of their gown or gloves.”
FDA aseptic guidance, page 17(opens the official source)FDA guidance, nonbindingChecked 24 Sep 2026
“Aseptic technique should be observed at all times, including the appropriate use of sterile tools for manipulations.”
Annex 1, clause 8.16(opens the official source)EU GMP Annex 1 (2022)Checked 24 Sep 2026
“An intervention that is an integral part of the aseptic process and is required for either set-up, routine operation and/or monitoring (e.g. aseptic assembly, container replenishment, environmental sampling).”
Annex 1, glossary: inherent interventions(opens the official source)EU GMP Annex 1 (2022)Checked 24 Sep 2026

The rule

The example rule from the demo

Rule R-02, version 1.0Example

Containers and closures are loaded as the line setup procedure shows: each component seated in its nest, trays level, and no touch on product-contact surfaces.

How it is detected
Trained detector. Checks how each component is placed and handled at the infeed.
Detector
loading 0.2.0Sample data
Cameras
CAM-02 RABS front, CAM-03 Component hopperExample
Site procedure
Filling line setup procedure, component loadingExample

The rule, cameras, procedure and detector are examples from the demo, shown as sample data. Your procedures set the real rule at setup, and your quality unit approves it.

How the camera sees it

What the camera has to see

A trained detector watches the infeed and checks how each component is placed and handled against the rule. When loading doesn't match it, the detector opens a case with the clip, and a reviewer decides what it means.

What happens to a detection

From a detection to a signed record

Every detection follows the same path, and a person decides each one.
  1. A case opens

    The detector opens a case with its own ID, the detection time from the site clock, the camera, area and shift, the rule and its version, and the detector version.

  2. A reviewer decides

    A trained reviewer watches the clip and confirms, dismisses or escalates the case with a reason from a fixed list. Only a quality lead closes an escalation.

    Read more about a reviewer decides
  3. The event record

    Each case prints as an event record: what the camera saw, the rule and its sources, and every decision, ready to attach to an investigation in your own system.

  4. The report

    The Aseptic Behavior Monitoring Report counts every case in the period, with trends and the audit trail, and your quality unit signs it.

EV-20260925-00625 Sep 2026 15:53:09 ET

Bottle tray loaded tilted against the guide rail.

A sample case from the demo. Sample data.

Status

Where it stands in the product

  • Running in the demoComponents loaded incorrectly at the infeed. Running in the demo as condition C2, with example rule R-02 version 1.0 and detector loading 0.2.0. Sample data.

Sources

Every passage behind this practice

Each passage links to the official text and shows the date it was last checked word for word.

Questions

Common questions

Is loading components an intervention?
Annex 1 lists container replenishment among its examples of inherent interventions, the ones that are part of the routine aseptic process. Your procedure decides which loading steps it treats that way.
What does a loading case show the reviewer?
The clip and frames, the camera, the time from the site clock, the rule and its version, and the detector and its version. The reviewer confirms, dismisses or escalates the case with a reason from a fixed list.
Can we use our own loading procedure?
Yes. The rule on this page is the demo example. At setup your team writes the rule from your line setup procedure, and your quality unit approves it.

See it with sample data

We show the review queue, a signed monitoring report, the audit trail review and the validation package, then answer your team's questions.

Request a walkthrough