Practices

Disinfection technique on camera

Your disinfection procedure sets how surfaces are wiped: the technique, the number of strokes and the direction. No regulation spells these out, so a camera checks them against your own procedure.

What it covers

Disinfection, in plain words

This category covers how surfaces are wiped during cleanroom disinfection, from the technique to the direction of each wipe. The rules come from your procedure. Annex 1 asks for cleanrooms to be cleaned and disinfected under a written program, and FDA's aseptic processing guidance asks for disinfection procedures detailed enough to be repeated the same way.

More practices

Practices covered on this page

These practices share a page with the category, since each one answers the same question as the others here.

Surface disinfection technique not followed

In the condition library

Wiping each surface the way your disinfection procedure describes, in its order and with its technique. No regulation spells out the technique, so the rule comes from your procedure; 21 CFR 211.42 asks aseptic areas to have a system for cleaning and disinfecting the room and equipment.

In the condition library: added at setup with its own rule, cameras, limit and detector.

No regulation states this behavior directly; the site procedure is the source.

More wipe strokes than the site limit

In the condition library

Staying within the number of wipe strokes your procedure sets. The limit is your site's own, so your procedure is the source; FDA's aseptic processing guidance asks for disinfection procedures described in enough detail to be reproduced.

In the condition library: added at setup with its own rule, cameras, limit and detector.

No regulation states this behavior directly; the site procedure is the source.

Wipe pattern not unidirectional

In the condition library

Wiping in a single direction, as your procedure sets. No regulation names the pattern, so the rule is your site's own, under the written disinfection program Annex 1 asks for.

In the condition library: added at setup with its own rule, cameras, limit and detector.

No regulation states this behavior directly; the site procedure is the source.

Shared regulations

The passages these practices share

Quoted word for word from the official texts, with the date each was last checked.
“The disinfection of cleanrooms is particularly important. They should be cleaned and disinfected thoroughly in accordance with a written programme.”
Annex 1, clause 4.33(opens the official source)EU GMP Annex 1 (2022)Checked 24 Sep 2026
“Disinfection procedures should be described in sufficient detail (e.g., preparation, work sequence, contact time) to enable reproducibility.”
FDA aseptic guidance, page 38(opens the official source)FDA guidance, nonbindingChecked 24 Sep 2026

Questions

Common questions

Why do these rules come from our own procedure?
No regulation states wipe technique, stroke counts or direction. Annex 1 and FDA's guidance ask for a written disinfection program in enough detail to repeat, and your procedure sets the steps the camera checks.
Where does the camera watch disinfection?
Wherever your procedure has surfaces wiped and a camera can see them. At setup your team chooses the cameras and surfaces each rule covers, and your quality unit approves the rule.
Who decides what a disinfection case means?
A trained reviewer watches the clip and confirms, dismisses or escalates the case with a reason. Your quality unit decides what a confirmed case means for the area.

See it with sample data

We show the review queue, a signed monitoring report, the audit trail review and the validation package, then answer your team's questions.

Request a walkthrough