Practices

Aseptic technique monitoring

Aseptic technique is how people move and handle things around sterile product. These are the parts of it a camera can check, each with a written rule and a person who decides every case.

What it covers

Aseptic technique, in plain words

This category covers how people move and work next to open product and the critical area, from how fast they walk to where their hands go. Each practice traces to passages in EU GMP Annex 1, FDA's aseptic processing guidance or 21 CFR 211, and the passages they share are quoted below.

The practices

Each practice and its status

  • Moving too fast in the filling room

    Running in the demo

    Walking pace in the filling room, measured against the limit in your rule.

  • Reaching over open containers

    Running in the demo

    Hands, gloves or arms passing above open containers, including through the glove ports.

  • How much operators move next to the critical area

    A requirement a camera can check

    How much operators move right next to the critical area while product is exposed.

  • Hands touching vials at the capping station

    A requirement a camera can check

    Hands touching vials where people step in at the capping station.

Shared regulations

The passages these practices share

Quoted word for word from the official texts, with the date each was last checked.
“Appropriate written procedures, designed to prevent microbiological contamination of drug products purporting to be sterile, shall be established and followed.”
21 CFR 211.113(b)(opens the official source)Binding US regulationChecked 24 Sep 2026

Questions

Common questions

Which of these run in the demo today?
Each practice shows its status. Running practices have an example rule and a detector in the demo. The others come from the product's condition library or its list of requirements a camera can check.
Does camera monitoring replace observation by aseptic experts?
No. Annex 1 asks for regular observation of aseptic operations by people with expertise in aseptic processing. Camera monitoring adds a continuous record of behavior for your team to review alongside it.
Who writes the rules?
Your team. Each rule comes from your own procedures and your quality unit approves it. The rules on these pages are examples.
Does a detection count as a deviation?
Not on its own. A reviewer decides every case. If a case needs investigating, a quality lead closes it with the deviation or CAPA number from your own system, where the investigation lives.

See it with sample data

We show the review queue, a signed monitoring report, the audit trail review and the validation package, then answer your team's questions.

Request a walkthrough