Aseptic technique
Reaching over open containers
Under downward unidirectional airflow, anything above an open container is upstream of the product, so aseptic work comes in from the side. A camera can watch the zone above the containers and open a case when a hand crosses it.
The practice
In plain words
At the filling line, people keep their hands, gloves and arms out of the air above open containers, including when they reach in through the glove ports. They approach from the side instead. Clean air flows down onto the product, so particles from anything above it can be carried straight in.
Running in the demoPart of Aseptic technique
Why it matters
In the regulators' words
“To maintain sterility of nearby sterile materials, a proper aseptic manipulation should be approached from the side and not above the product (in vertical unidirectional flow operations).”
“Keep the entire body out of the path of unidirectional airflow”
“Movement adjacent to the critical zone should be restricted and the obstruction of the path of the unidirectional (first air) airflow should be avoided.”
“Appropriate written procedures, designed to prevent microbiological contamination of drug products purporting to be sterile, shall be established and followed.”
The rule
The example rule from the demo
Rule R-03, version 1.0Example
No hand, glove or arm passes above open containers, including through the RABS glove ports. Manipulations approach from the side.
- How it is detected
- Trained detector. Tracks arms and gloves against the zone above open containers.
- Detector
- reach 0.3.0Sample data
- Cameras
- CAM-02 RABS frontExample
- Site procedure
- Aseptic behavior procedure, work at the RABSExample
The rule, cameras, procedure and detector are examples from the demo, shown as sample data. Your procedures set the real rule at setup, and your quality unit approves it.
How the camera sees it
What the camera has to see
A trained detector tracks arms and gloves at the filling line against the zone above the open containers. When a hand, glove or arm passes through that zone, it opens a case with the clip, and a reviewer decides what it means.
- Detection method: How the camera watches zones near open product(opens conductscience.com)
What happens to a detection
From a detection to a signed record
A case opens
The detector opens a case with its own ID, the detection time from the site clock, the camera, area and shift, the rule and its version, and the detector version.
A reviewer decides
A trained reviewer watches the clip and confirms, dismisses or escalates the case with a reason from a fixed list. Only a quality lead closes an escalation.
Read more about a reviewer decidesThe event record
Each case prints as an event record: what the camera saw, the rule and its sources, and every decision, ready to attach to an investigation in your own system.
The report
The Aseptic Behavior Monitoring Report counts every case in the period, with trends and the audit trail, and your quality unit signs it.
EV-20260926-00126 Sep 2026 08:28:10 ET
Arm passed above open bottles at the infeed while using glove port 2.
A sample case from the demo. Sample data.
Status
Where it stands in the product
- Running in the demoReaching over open containers. Running in the demo as condition C3, with example rule R-03 version 1.0 and detector reach 0.3.0. Sample data.
Sources
Every passage behind this practice
- FDA aseptic guidance, page 18(opens the official source)States this requirement. Checked 24 Sep 2026
- FDA aseptic guidance, page 17(opens the official source)Broader requirement this falls under. Checked 24 Sep 2026
- Annex 1, clause 7.18(opens the official source)Broader requirement this falls under. Checked 24 Sep 2026
- 21 CFR 211.113(b)(opens the official source)General cGMP duty. Checked 24 Sep 2026
Questions
Common questions
- Does reaching in through a glove port count?
- In the demo's example rule, yes: no hand, glove or arm passes above open containers, including through the RABS glove ports. Your procedure sets the real rule.
- Does every reach become a finding?
- No. Each detection opens a case, and a trained reviewer confirms, dismisses or escalates it with a reason. A reach your procedure allows is dismissed as allowed by the procedure in this case, and that decision stays in the record.
- Why approach from the side?
- In vertical unidirectional airflow, the air above an open container flows onto it. FDA's guidance asks for a side approach to keep nearby sterile materials sterile.
- Where does the camera need to be?
- Where it can see the open containers and the glove ports from the front. In the demo that is the camera on the RABS front; for your line, the site survey places the cameras.
See it with sample data
We show the review queue, a signed monitoring report, the audit trail review and the validation package, then answer your team's questions.