Gloves

Glove disinfection before sterile handling

Your glove procedure has gloves disinfected before they handle sterile supplies and between uses of the glove ports. A camera can follow those steps at the RABS and open a case for a reviewer when one is skipped.

Illustration, not camera footage. CAM-02 RABS front, 26 Sep 2026 10:58:31 ET. Front view of the RABS: glove ports 1 to 4 on the barrier panel, a glove spray station outside the barrier and the stopper bowl inside. Subject 1 is tagged. Detection moment. Flagged: a hand leaves glove port 2 and goes into glove port 3 with no glove spray step in between.GLOVE SPRAYSTOPPER BOWLHEPA1234Subject 1No disinfection between portsCAM-02 RABS front26 Sep 2026 10:58:31 ETILLUSTRATIONT 0 s
A drawn illustration of a detection from the demo, not footage. In your system this is the recorded clip, kept on your site network. Sample data.

The practice

In plain words

At a RABS, operators reach in through gauntlet gloves fixed in the glove ports. Your procedure says when gloves are disinfected, such as before they handle sterile supplies and between uses of the glove ports. A missed disinfection lets whatever a glove picked up on one task travel to the next, right beside open product.

Running in the demoPart of Gloves

Why it matters

In the regulators' words

Annex 1 asks for gloves to be disinfected regularly during operations, and for RABS gloves exposed to the background environment to be disinfected after each exposure. FDA's guidance asks for sterile gloves to be sanitized or changed regularly to minimize the risk of contamination.
“Gloves should be regularly disinfected during operations. Garments and gloves should be changed immediately if they become damaged and present any risk of product contamination.”
Annex 1, clause 7.16(opens the official source)EU GMP Annex 1 (2022)Checked 24 Sep 2026
“If exposed to the background environment during operation, disinfection using an approved methodology following each exposure should be completed.”
Annex 1, clause 4.21(ii)(opens the official source)EU GMP Annex 1 (2022)Checked 24 Sep 2026
“After initial gowning, sterile gloves should be regularly sanitized or changed, as appropriate, to minimize the risk of contamination.”
FDA aseptic guidance, page 17(opens the official source)FDA guidance, nonbindingChecked 24 Sep 2026
“Appropriate written procedures, designed to prevent microbiological contamination of drug products purporting to be sterile, shall be established and followed.”
21 CFR 211.113(b)(opens the official source)Binding US regulationChecked 24 Sep 2026

The rule

The example rule from the demo

Rule R-04, version 1.0Example

Gloves are disinfected before handling sterile supplies and between uses of the RABS gauntlet gloves.

How it is detected
Sequence check. Looks for glove disinfection between glove port use and sterile handling.
Detector
glove-sequence 0.3.0Sample data
Cameras
CAM-02 RABS frontExample
Site procedure
Glove disinfection procedure, including gauntlet glovesExample

The rule, cameras, procedure and detector are examples from the demo, shown as sample data. Your procedures set the real rule at setup, and your quality unit approves it.

How the camera sees it

What the camera has to see

The detector follows the order of steps at the RABS: glove port use, glove disinfection, then sterile handling. When sterile handling or the next glove port use comes without disinfection first, it opens a case with the clip, and a reviewer decides what it means.

What happens to a detection

From a detection to a signed record

Every detection follows the same path, and a person decides each one.
  1. A case opens

    The detector opens a case with its own ID, the detection time from the site clock, the camera, area and shift, the rule and its version, and the detector version.

  2. A reviewer decides

    A trained reviewer watches the clip and confirms, dismisses or escalates the case with a reason from a fixed list. Only a quality lead closes an escalation.

    Read more about a reviewer decides
  3. The event record

    Each case prints as an event record: what the camera saw, the rule and its sources, and every decision, ready to attach to an investigation in your own system.

  4. The report

    The Aseptic Behavior Monitoring Report counts every case in the period, with trends and the audit trail, and your quality unit signs it.

EV-20260926-00426 Sep 2026 10:58:31 ET

Moved from glove port 4 to port 1 with no glove disinfection seen.

A sample case from the demo. Sample data.

Status

Where it stands in the product

  • Running in the demoGloves not disinfected before sterile handling or between glove ports. Running in the demo as condition C4, with example rule R-04 version 1.0 and detector glove-sequence 0.3.0. Sample data.

Sources

Every passage behind this practice

Each passage links to the official text and shows the date it was last checked word for word.

Questions

Common questions

What counts as disinfecting the gloves?
Whatever your glove disinfection procedure sets, such as the disinfectant and how it is applied. The detector checks that the step happens in order; your procedure defines the step.
What about glove changes?
Glove changes are separate practices in the condition library, such as changing gloves after touching the floor or when moving between filling lines. The gloves category lists them with their sources.
Is this the same as glove sampling?
No. Glove sampling tests what is on the gloves. A separate practice checks that gloves aren't sanitized just before samples are taken, since that can hide what was there.

See it with sample data

We show the review queue, a signed monitoring report, the audit trail review and the validation package, then answer your team's questions.

Request a walkthrough